Comet MS55D - Sixteen Channel Data Logger with Alarms

Comet MS55D - Sixteen Channel Data Logger with Alarms

Brand: Comet

SKU: 234459

Category: Test & Measurement Accessories > Data Loggers

Price: RM 12614.00

Dealer Price: RM 29945.22 (for bulk orders)

Availability: 3-7 days

Product Description

Comet MS55D Measure and process 1 to 16 input variables Each of the 16 channels offers the virtual channel (countable) Acquire autonomous recording of measured values On-line monitoring of measured values ​​and states 16 Channel Data Acquisition Monitoring System w/Display The complete solution for monitoring temperature, humidity, and other values. Data loggers are designed for measuring, recording, evaluation, and subsequent processing of input electrical signals, which are subject to relatively slow changes (> 1s). In conjunction with the appropriate sensors and transducers are suitable for monitoring physical quantities. The device includes a Traceable Calibration Certificate with declared metrological traceability of etalons is based on requirements of EN ISO / IEC 17025. The calibration sheet is always loaded as modules. If the defined required configuration of inputs by, calibration certificate proves calibration inputs according to the required configuration - more than one range for each of the 16 inputs. Each from 16 channels offers: Independent hysteresis, delay Setting up 4 conditions for an alarm Alarms by: GSM modem Emails Phone dialer Integrated buzzer External siren or light Relay Applications: Food and beverages industry (HACCP) Server rooms, data centers Server rooms, data centers Pharmaceutical industry (GMP) Blood stations, pharmacies Horticulture and cultivation of plants HVAC - heating, ventilation, air conditioning, cooling Building and energy management Building automation Research and development Laboratories (GLP) Common Connectivity Options Monitoring system MS may be configured for almost any desired measurement application. Sensors can be wired to datalogger in star-like connection as well as in serial. Combination of both is also possible. The monitoring system MS is characterized by a wide range of communication interfaces such as the RS232, RS485, USB, Ethernet and GSM or GPRS modem. Thanks to Wi-Fi routers several measuring systems MS can be wirelessly connected to a network. Features of Ethernet Interface Ethernet interface Data logger is designed for connection to standard computer network. The 10 and 100Mb/s Ethernet is supported. No need to build new data lines. Thanks this installation cost are essentially reduced and instant easy start of monitoring system operation is enabled. Modbus protocol Enables to read actually measured values by means of industrial standard Modbus. Data is available in several formats. Protocol is suitable for implementing of MS data logger to SCADA system. SNMPv1 protocol Actually measured values can be acquired by means of SNMPv1 protocol. MIB tables are available for free. Designed especially for IT applications and use in “managed” computer networks. Fast data download Record download speed was increased four-times from previous MS5 data logger generation. SOAP protocol Protocol designed for data logger integration to own www infrastructure. Available actual values can be captured by www server (Apache, IIS) and processed by the user. Communication protocol SOAP version 1.1. is supported. By means of this protocol data logger sends actual values in preset intervals to specified server. Syslog protocol Syslog message is sent after alarm state or data logger error appears. Syslog is compatible with RFC5424. E-mail Data logger sends warning emails up to three different addresses. E-mail is immediately sent after alarm state of monitored technological process appears. User is also informed on error states of device itself (measuring channel error, fulfilling of internal memory, self-test error). SMTP servers requiring autentization are also supported. XML file Actual values can be downloaded to XML file. This option is suitable for data logger integration to SCADA systems. Data logger display Network parameters can be set directly from data logger display. It is possible to change IP address, subnetwork mask and initial gate. Secured WEB server WWW server is built in the device. Here it is possible to monitor actual values, alarm states and information on data logger. Also access password for www pages can be entered. WWW pages are user modifiable. Free SDK description is available to create own www pages. SNMP Trap SNMP Traps are sent after alarm state or device error appears. Database system Prepared for connection to database system including online values transfer. WWW remote conditions Control of remote condition and relays is enabled also via www interface. In The Box Datalogger including the Battery Traceable Calibration Certificate Calibration of other ranges is optional USB Communication Cable Basic Manual Free Basic Windows Software Manuals/Guides Brochures Comet Monitoring Systems Catalog Manuals Comet System MS6 Series Instruction Manual Spec Sheets Comet System MS55D Data Sheet HOBO - Onset MX1104 - Department - Siderail - Q2 - 23 Manufacturer Specs Types of Data Logger Inputs Measured values Module types Range Accuracy Notes Current DC A0 4 ... 20mA ±0.1% FS with source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet). only galvanic not isolated A1* 4 ... 20mA for passive sensing of current, Rvst = 14 Ohms B0* 0 ... 20mA input resistance Rvst = 14 Ohms B1* 0 ... 1A input resistance Rvst = 0,04 Ohms B2* 0 ... 5A AC C0 0 ... 20mA ±1% FS galvanic isolated, sinusoidal signal at a frequency of 50 Hz input resistance Rin by type 0.04 Ohm to 14 Ohms C1 0 ... 1A ±1% FS C2 0 ... 5A Voltage DC D0* 0 ... 100mV ±0.1% FS input resistance Rin by a 900 kOhms to 10 Mohms D1* 0 ... 1V D2* 0 ... 10V D4* 0 ... 75V D5* -10V ... +10V ±0.1% FS (± 20 mV) AC E0 0 ... 100mV ±1% FS only galvanic isolated, sinusoidal signal at a frequency of 50 Hz input resistance Rin by type 700 kOhms to 10 Mohms E1 0 ... 1V E2 0 ... 10V E4 0 ... 50V Resistance F* necessary to specify a range ±0.1% FS two-wire connection Temperature probes Pt and Ni Ni1000 J* -50°C ... +250°C ±0.2°C (-50°C ... 100°C) Ni1000/6180 ppm, two-wire connection ±0.2% MH (100°C ... 250°C) measuring current of approximately 0.25 mA continuously Pt100 K* -140°C ... +600°C ±0.2°C (-140°C ... +100°C) Pt100/3850 ppm, two-wire connection ±0.2% MH (+100°C ... +600°C) measuring current of approximately 2 mA continuously Pt1000 K1* -140°C ... +600°C ±0.2°C (-140°C ... +100°C) Pt1000/3850 ppm, two-wire connection ±0.2% MH (+100 ... +600°C) measuring current of approximately 0.2 mA continuously Pt1000 K3 -10°C ... +50°C ±0.06°C Pt1000/3850 ppm, two-wire connection measuring current of approximately 0.2 mA continuously. Only galvanically not isolated. Thermocouple K (NiCr-Ni) N* -70°C ... +1300°C ±0.3% MH + 1.5°C linearized, cold junction compensation, datalogger must be placed in recommendend working position T (Cu-CuNi) T* -200°C ... +400°C J (Fe-Co) O* -200°C ... 750°C S (Pt10%Rh-Pt) P* 0°C ... 1700°C ±0.3% MH +1.5°C(200°C ... 1700°C) B (Pt30%Rh-Pt) Q* 100°C ... 1800°C ±0.3% MH+1.0°C (300°C ... 1800°C) linearized, without cold junction compensation Binary signal potential-less contact S* binary signal maximum resistance of closed contact is 1000 ohm minimum duration for recording is 200ms voltage, galvanically isolated S1 voltage for „H“ state is 3 V to 30 Vdc @ 9 mA max minimum duration for recording: 200ms galvanically isolated Pulse counter potential-less contact, galvanically isolated CTU 31 bits, 5kHz max. voltage change of the counter state is 3V to 24VDC backup power, filter bouncing galvanically isolated potential-less contact, open connector CTK maximum resistance of closed contact is 10 kOhms minimum open contact resistance is 250 kilohms backup power, filter bouncing Frequency input voltage signal measurement, galvanically isolated FU 0 ... 5kHz ±(0.2% MH + 1Hz) input voltage for "H": 3V to 24V DC @ 7 mA minimum duration of input pulse: 30us resolution 1Hz galvanically isolated measurement frequency switching contact, galvanically not isolated FK 0 ... 5kHz maximum resistance of closed contact is 10 kOhms minimum open contact resistance is 250 kOhms resolution 1Hz minimum duration of input pulse: 30us RS485 input for serial signal RS485 RP digital transmission input supports Modbus RTU or Advantech connected devices must have the same communication parameters input can work with up to 16 devices galvanically isolated, MS can be equipped with multiple RF modules* Inputs marked with asterisk (*) are available also as galvanically isolated. Galvanic isolation is not designed as safety protection. General Specifications Total memory capacity 2MB (up to 480 000 values) Memory type internal SRAM, backed-up by Lithium battery Data logging modes noncyclic - logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new Data logging interval adjustable individually for all input channels from 1 second to 24 hours Real time clock year, leap year, month, day, hour, minute, second, backed-up by Lithium battery Input measured values (1 to 16 inputs) are defined for each channel by installed input modules (see table) accordingly to user requirements Resolution of the AD converter (analog channels) 16 bits, conversion duration approximately 60ms/channel Communication speed 9600, 19200, 57600, 115200 Bd, 230400* Bd (* applicable for USB, Ethernet) Power 9 to 30Vdc, 24Vdc recommended Operating temperature range 0 to +50°C Dimensions including connectors 215 x 225 x 60 mm Protection IP20 Weight approximately 800 g Warranty 3 years Tech Specs Test Equipment General Attributes Warranty 3 YEARS Interfaces I/O LAN / Ethernet, USB IP Rating IP20 Product Weight 800 GRAMS (1.76 LBS) Product Height 8.86 IN Product Length 2.36 IN Product Width 8.46 IN Battery Type Li-Polymer Power Supply Voltage Battery Powered Country of Origin Czech Republic

Product Features

  • Quality assured industrial and office supplies
  • Available for B2B wholesale purchase
  • Genuine Comet product
  • Fast delivery across Malaysia
  • Competitive wholesale pricing for businesses

Order Now

Ready to order Comet MS55D - Sixteen Channel Data Logger with Alarms? View product details and add to cart for fast delivery to your business.

For bulk orders and dealer pricing, register a business account today.